Selection of refrigerant magnetic pump
Today, a customer needs to select a suitable magnetic metering pump for quantitative filling of R134a R410 refrigerant
This is the detailed information of the on-site working conditions provided by the customer:
Medium:
The viscosity of R134a is (25℃)/Pa.s liquid 0.202cps
The viscosity of R410 is (25℃)/Pa.s liquid 0.12cps
Flow range: nominal 68 GPH at 3500 RPM, equivalent to 4284 ml/min
12v brushed motor
Working pressure: 6.89bar
Outlet pressure: Maximum 12.07bar
Flow range: 3150-4725ml/min
The viscosity of the liquid is very low. He wants to know whether our magnetic pump can meet his needs and whether the
pressure can meet his needs?
After analysis, our technicians recommended our
magnetic pump CX-1.5-72-170W DC brushless built-in drive motor
If you are also troubled by the selection of precision metering pumps and want to know the specific industrial pump selection
and quotation issues, please consult CIXIFM winny:
Email: sales01@cxflowmeter.com