新闻资讯PCBanner 新闻资讯wapBanner
首页 > Application > CHEMICAL > Selection of chemical liquid mixture metering pump

Selection of chemical liquid mixture metering pump

Date:2025-03-27 source:Shanghai JSN Micro Flow Meter CO.,LTD

 Email: sales01@cxflowmeter.com

whatsapp: 008618049841995




Selection of chemical liquid mixture metering pump


Today, a customer inquired about the selection of water (35%) + acetic acid (25%) + hydrogen peroxide (25%) + peracetic acid (15%) 

chemical liquid mixture metering pump


He provided the following detailed information:


Medium: water (35%) + acetic acid (25%) + hydrogen peroxide (25%) + peracetic acid (15%)

Flow rate: 2-20ml/m at the beginning, up to 50ml/m at room temperature

Outlet pressure is up to 3bar, usually 1-2bar

With stepper motor


CIXI gear metering pump.jpg


After analysis by our technicians, the following recommended information was given:

Recommended 0.15CC magnetic pump, material 316+PEEK, this material should be confirmed with the customer whether it is resistant to

 his medium.


It is not recommended to match the motor with a stepper, and it is best to choose a servo motor with pressure. If you must choose a 

stepper motor, then choose a 0.3CC magnetic pump head.


If you also encounter specific chemical liquid metering pump selection and quotation issues, please consult CIXIFM winny:

 Email: sales01@cxflowmeter.com

whatsapp: 008618049841995




Share to: