Today, a customer asked about the selection of compressed air flow meter. At first,
he said he needed a DN200 thermal mass flow meter
He provided the following parameters:
Medium: compressed air
Working pressure: 0.8Mpa
Maximum flow: 15000m³/h
Range ratio ≥100:1
Accuracy level: ≤1.0
Later, our technicians analyzed
Recommended Coriolis flow meter for him
The following is the parameter information of Coriolis flow meter:
Coriolis mass flow meter DN200
Medium: compressed air
Rated flow 15000 cubic/H
Accuracy: 1%
Installation method: flange connection
Installation size: DN200
With LCD display
Material: 316L
Temperature: -30-150°C
Pressure: 1.6MPa
Output: 4-20 mA +485
Power supply: 24V M20*1.5
Explosion-proof level :ExdIIBT4