新闻资讯PCBanner 新闻资讯wapBanner
首页 > Flow Meters' Diary > News of Flow Meter > diethylene oval gear flow sensor
Submit a message
  • Name*
  • Tel*
  • Email*
  • Content*
  •  

Friendship tips

    Shanghai JSN Micro Flow Meter CO.,LTD as a high-tech industrial products manufacturing and complete sets of product sales, R & D, production, processing and sales as one, with independent import and export rights of enterprises.
    The company's main flow meter, level meter, and pressure controller, temperature controller, analytical instruments and other various types of instrumentation. To solve all kinds of problems, and provide complete sales service for customers with professional technical point of view.
International service telephone
(86)021-57632436

diethylene oval gear flow sensor

Date:2018-01-02 source:

  diethylene oval gear flow sensor   email: porter@microflowmeter.com

Shanghai JSN Micro Flow Meter CO.,LTD is theprofessional supplier for oval gear flow meter ,mass flow meter,electromagneticflow meter,micro flow meter,gear pump.The products are widely used for Petroleum,petrochemical, chemical, metallurgy, nuclear industry, environmentalprotection, electricity, national defense, medicine, food and other fields, andexported to foreign countries. The company was founded in 2011 by Siemens engineersand has advanced CNC machining centers in the country. Since its inception, thecompany has continued to profit, has developed steadily, has strong technicalequipment and human resources, and has provided a large number of high-qualitymetering products for various industries in the national economy.

 diethylene oval gear flow sensor

diethylene oval gear flow sensor

At presentdomestic Oval gear flow meter structure is complex, bulky, bulky, noisy, smallscale, not suitable for low viscosity liquid, the market is more common withDTO series and OGM series. For these problems the country has been unable toovercome, while the Shanghai JiShen instrument Instrument company oval gear Ovalgear flow meter does not have the above problems, such as the same DN25caliber, our model CX-M25-AL, flow range: 0.5 ~ 100L / M, range of 1: 200 orhigher, and weighs only 1.5KG , While the DTO-25, the flow of 600-6000L / H,range ratio of only 1:10, the weight of up to 23KG. All this due totechnological breakthroughs, our chief engineer Tu workers, he is a formerSiemens senior engineer, the use of equipment It is also Siemens CNC MachiningCenter with cutting accuracy up to 0.001mm, which ensures that we produce highquality flow meters.

SinceMay 23, 2011, Shanghai Jinshen Instrument Co., Ltd. successfully released a newoval gear flow meter CX-M and G series, the liquid flowmeter range than thefirst in China reached more than 1: 100, and at the same time to ensureaccuracy 0.5% above the flowmeter industry model.From this since the base meterhas been a pioneer in flowmeter technology, but also one of the high-endflowmeter brand.The perfect technical level, excellent quality standards,innovation has been innovation Wells said. Deep base flow meter has been toprovide customers with a reliable use of the experience in the past rely on theimport of the era, the customer has been a headache for after-sales service,and base deep flow meter with 8 years of use of the long life, in one fellswoop cracked this situation.

oval gear flow sensor

diethylene oval gear flow sensor

The Ovalgear flow meter is a volumetric flow meter that consists of a flow chamber in achamber and one or several elements that are rotated by fluid flow to form aflow meter. Leakage between the rotating element and the inner wall and theselected working range The internal flow rate is negligible. The rotation ofthe element is transmitted mechanically or by other means to the indicatingdevice to indicate the volume flow of the fluid flowing through.

 diethylene oval gear flow sensor

diethylene oval gear flow sensor

Technicaldata of Gear type flow meter

Model

K-factor

Minimum  flow

Flow  range

Accuracy

G0.025

0.025ml

0.001L/Min

0.008~2L/Min

0.5%

G0.04

0.04ml

0.004L/Min

0.2~4  L/min

0.5%

G0.1

0.4ml

0.008L/Min

0.01~8L/min

0.5%

G0.2

0.245ml

0.01L/Min

0.16~16  L/min

0.5%

G0.4

0.4ml

0.01L/Min

0.16~16  L/min

0.5%

G1

1.036ml

0.02L/Min

0.4~80  L/min

0.5%


What are the precautions for the gear flow meter?

1) When the flow exceeds the specified maximum flow rate, the Oval gear flow meter wear increases with the increase of the rotation speed, and the pressure loss increases sharply, should be avoided. Less than the minimum flow, although still able to measure, but the error increases. Flow meter The starting flow is about 2% of the maximum flow, and the normal working flow is preferably 70%-80% of the maximum flow.

2) Deep-rooted flowmeter is used with various viscosity media from 0.3 ~ 100000cps, different viscosity media will affect the range, the following single must be noted

3) The measured liquid temperature should not exceed the specified value, otherwise, the instrument can not work properly, or even stuck, the counter part is easily damaged at high temperatures. Liquid temperature changes will also cause additional errors in viscosity.