Email:sales01@cxflowmeter.com
whatsapp:008618049841995
Selection of air vortex flow meter
Today, a customer wanted to measure air flow, but the flow range to be measured is relatively large, 0-2000m3/h.
The customer did not know how to choose a suitable air flowmeter
He provided us with the following information:
Medium: air,
Pressure 60kpa,
Temperature normal temperature
Flow 0-2000m3/h,
Using one vortex flowmeter cannot measure the full range, multiple vortex flowmeters are required to measure,
the smaller the minimum flow, the better, which flowmeters are recommended to use, and whether to install multiple
pipes or one pipe in parallel
After analysis, our technicians told him that there are several options:
Vortex flow meter, if using conventional type, at least 4 calibers are required:
DN15:4-12 cubic
DN32:15-120 cubic
DN80:80-800
DN15:180-2000
Use high-end type, 3 calibers
DN15:3-18
DN40:14-250
DN80:40-2000
If you choose a thermal flow meter, choose 2 calibers:
DN15:0.65-65
DN65 (high flow rate): 12-2400
It is recommended to install multiple pipes
If you are also confused about the selection of gas flow meters and air flow meters, please consult CIXIFM winny:
Email:sales01@cxflowmeter.com
whatsapp:008618049841995

hotline
(86)021-57632436