Liquid turbine gasoline flowmeter

Date:2019-12-13 source:

It is common to use liquid turbine flowmeter to accurately measure vehicle gasoline. The following is a detailed introduction to relevant professional knowledge of liquid turbine vehicle gasoline flowmeter.

The liquid turbine vehicle gasoline flowmeter is a kind of high precision flow-measuring instrument, which can be used to accurately measure the flow-rate and production-rate of the liquid with relative flow-integrating instruments.Widely used in crude oil, chemical plant, metallurgical industry, scientific research and other industries of metrological verification, automatic control system.Turbine flow sensors equipped with environmental hygiene connectors can be used in pharmaceutical, food and other manufacturing industries.

Liquid turbine gasoline flowmeter

Liquid turbine gasoline flowmeter

1, working pressure damage is small, impeller with anti-corrosion effect;

2, choose the excellent super power consumption single chip microcomputer technology, the whole equipment is strong, low power, the most useful.

3. Intelligent flow display screen with compensation effect of discrete system precision.

4. The index of the dashboard can be set online for free by the function keys, and the display information can be displayed on the LCD screen. The LCD screen is clear and highly reliable.

5. EEPROM is selected to maintain the accumulated flow and exponential power loss of the instrument panel, with the maintenance time exceeding 10 years.

6. The performance MCU microprocessor is selected to collect data and solve the display information output and accumulate the instantaneous velocity flow.

7. All hard alloy tools (cobalt alloy) are used to shield the cantilever beam to construct the rolling bearing, which integrates the rotating rolling bearing and the pressure bearing to further improve the service life of the rolling bearing, and can work in the material with a small amount of fine sand and waste.

8. Use 1Cr18Ni9Ti stainless steel plate structure, with good corrosion resistance.

9, very easy to overhaul, self-rectifier structure, small and medium-sized light, simple structure, can be disassembled in a short period of time.

10. Easy internal cleaning.

11. Strong diamagnetic effect and vibration working ability, reliable characteristics and long service life.

12. Low water limit flow, wide detection range.

14, corrosion resistance, suitable for strong acid and alkali water solution.

Pay attention to the following for the maintenance of part of liquid turbine vehicle gasoline flowmeter sensor:

1. During application, the material under test should be cleaned without chemical fibers, particles and other residues.

2. In the initial application of turbine flow sensor, the sensor should be slowly filled with material, and then the inlet and outlet gate valves (gate valves should be installed at the back end of the flow meter) should be opened, so as to prevent the sensor from being impacted by high velocity hydrodynamics when there is no material.

3. The maintenance cycle time of turbine flow sensor is generally about half a year.Repair and cleaning, warm reminder not to damage the accurate measurement chamber parts, very impeller.Please pay attention to the connection between the guide piece and the impeller when assembling the line.

4. When the turbine flow sensor is not needed, the internal material should be cleaned. After drying, safety protective covers should be added on both sides of the sensor to prevent dust from entering.

5, the applicable filter device should be cleaned on time, when there is no need to clean the internal material, the same as the sensor, add dust cover, placed in a dry place for storage.

6. Before the installation of the sensor, blow or dial the impeller with the mouth to make it rotate quickly to check whether there is any display information. Then install the sensor when there is any display information.If no information is displayed, relevant parts should be checked for fault detection.

Porcelain city Shanghai instruments co., LTD., founded in 2011, founded by former Siemens engineers MrStone, specializing in high quality, high precision, high frequency, high temperature, high pressure, wide range of flow meter research and development production, production strictly enforce the ISO9001 standards, the use of independent research and development of technology, substitute the gaps in China's small flow meter, the product can completely replace the Max, KRACHT (clark), OVAL and other international brands.