新闻资讯PCBanner 新闻资讯wapBanner
首页 > Flow Meters' Diary > News of Flow Meter > surface active agent micro flow measurement
Submit a message
  • Name*
  • Tel*
  • Email*
  • Content*
  •  

Friendship tips

    Shanghai JSN Micro Flow Meter CO.,LTD as a high-tech industrial products manufacturing and complete sets of product sales, R & D, production, processing and sales as one, with independent import and export rights of enterprises.
    The company's main flow meter, level meter, and pressure controller, temperature controller, analytical instruments and other various types of instrumentation. To solve all kinds of problems, and provide complete sales service for customers with professional technical point of view.
International service telephone
(86)021-57632436

surface active agent micro flow measurement

Date:2017-02-01 source:
  surface active agent micro flow measurement  

email: porter@microflowmeter.com  Shanghai JSN Micro Flow MeterCO.,LTD is a manufactory  for Super MicroLiquid Flow Meter,Oval gear flow meter ,Mass Flow Meter,Circle Spur Gear FlowMeter,Gear Pump,Gear metering Pump etc. The company is a professional companyfor the production and supporting of automated instruments. It has strongtechnical force. The scientific research personnel account for more than 40% ofthe company"s total number of people. The production equipment is excellent andthe processing capability is strong. Since the new aviation instrument has anew and old research team, it not only produces the general-purpose flowmeasurement instrument in the market can also be designed and processedaccording to the user"s requirements in accordance with the user"s requirementsto solve the user"s various demands on the flow measurement.

 surface active agent micro flow measurement

surface active agent micro flow measurement

Ovalgear flow meter  is widely used inpetroleum, chemical and hydraulic industries due to its advantages of highprecision, simple installation, stable performance and goodrepeatability.However, the Oval gear flow meter that can be produceddomestically can only be applied due to the impatience of high pressure In thelow pressure occasion, the high pressure measurement occasion can only rely onthe foreign imported high pressure flowmeter.Therefore, the research of thehigh pressure Oval gear flow meter will help to expand the domestic applicationof the Oval gear flow meter and promote the development of the domestic flowmeasurement. Deep instrumentation independent research and development of the Ovalgear flow meter pressure up to 1000bar, it can be said has reached a higherlevel in the world, and obtain measurement certificate.

Oval gear flow meter, belonging to a type of volumetric flowmeter,cylindrical shape, with import and export, according to the media with a customfilter. Small size, light weight, easy installation, compact structure, withouttoo much maintenance; other The range ratio is very wide, generally more than1: 100, the minimum flow rate can be measured to 0.3ml / min; and thelinearization accuracy can reach 0.5% FS of full scale, so the use is very wideand can be used for measuring, regulating, controlling and distributing Highand low viscosity, or corrosive liquids, and there are health-type,explosion-proof for a special environment.

micro flow measurement

surface active agent micro flow measurement

The Ovalgear flow meter is a volumetric flow meter. The metering chamber is composed ofupper and lower end caps. The shell is formed by an oval gear rotor. The gearrotor meshes with the rotating shaft to convey the fluid. The permanent magnetarranged in the rotor is used for the detection of the rotor rotation. Twosensor holes are placed on the upper end to cover the detection sensor. Asealing ring is installed between the housing and the upper and lower end capsto prevent leakage of the measurement fluid. The base depth flowmeter is madeof a material with high wear resistance so that the flowmeter Can guaranteehigh precision measurement within the long service life.

 surface active agent micro flow measurement

surface active agent micro flow measurement

Maintechnical data of JSN micro oval Oval gear flow meter

CX-M2,flow range :0.5~150ml/min,accuracy 0.5%,G1/8"

CX-M3, flowrange:3~300ml/min,accuracy 0.5%,G1/8"

CX-M5, flowrange:5~1000ml/min,accuracy 0.5%,G1/8"

CX-M6, flowrange:0.5~100L/H,accuracy 0.5%,G1/4"

CX-M9, flowrange:6~600L/H,accuracy 0.5%,G1/4"

CX-M12,flow range:0.3~30L/Min, accuracy 0.5%,G1/2"

CX-M25,flow range:0.5~100L/Min, accuracy 0.5%,G1"


What are the precautions for the gear flow meter?

1) In the field installation, it should be noted that the direction of the arrow on the flow meter housing is consistent with the flow direction of the fluid;

2) The flowmeter is installed on the same pipe with the same nominal internal diameter as the inlet and outlet fittings. When the pipe is connected with the flowmeter, the seal should not protrude into the fluid;

3) The fluid to be measured shall be filled with the metering room of the flowmeter and the connecting pipes before and after it. If the fluid to be measured contains gas, a gas separator shall be installed before the flowmeter and the filter;