email: porter@microflowmeter.com Shanghai JSNMicro Flow Meter CO.,LTD.is a family company and it has more than 30 yearshistory. We are specialized in research of high quality flow meters, such as mircoflow meter,oval gear flow meter ,coriolis mass flow meter,electromagnetic flowmeter,piston flow meter, spur gear flow meter,gear pump,gear metering pump andso on. We devote ourselves to break the technology monopoly of foreigncountries. Our micro flow meter can replace Kracht, OVAL, SIKA and OMAGEforeign brands and so on. We have export our flow meters into more than 100countries and Shanghai JSN Micro Flow Meter CO.,LTD has already been a famous Automationinstrumentation company.

sandwich panels micro flow measurement
Withthe development of society, the state pays more and more attention to theprocess automation instrumentation industry. However, the Oval gear flow meter industryhas been in a vacancy and has been monopolized by major foreign brands such asMax, KRACHT, OVAL, etc. , People have long endured the expensive, longdelivery, the sale can not be resolved in time and so on, such as semiconductorchip cutting a set of equipment on the millions, once the instrument problems,loss unimaginable, the slayer saw these phenomena, Resolutely resigned assenior engineer in the position of Siemens, the establishment of ShanghaiJi-sheng Instruments Co., Ltd., with great concentration on research anddevelopment of gear flow meter. We have Oval gear flow meter has been awarded anumber of certificates, it is no exaggeration to say that Qishen production Ovalgear flow meter For example, many customers replace the OVAL LSF40 with ourCX-M5-AL because it costs less than half of the LSF40, but has twice the rangethan it does and has the same accuracy.
Ovalgear flow meter is a new type of volumetric flowmeter, in addition to apositive displacement flowmeter with high accuracy, the flow is not sensitiveto other advantages, there are the following advantages: Wide range, usually inthe flow meter is 10: l, and Deep flowmeter is generally 100: 1, or even 1000:1, the accuracy is still above 0.5%, suitable for high pressure flowmeasurement, the maximum pressure can reach 100Mpa, especially suitable for themeasurement of small flow, the minimum measurement limit can be 0.3ml / min ,Less affected by the viscosity characteristics of the medium, suitable for flowmeasurement under various viscosity conditions.

sandwich panels micro flow measurement
Ovalgear flow meter Through the rotation of the gear cavity, through a series ofdeceleration and speed ratio adjustment mechanism, directly connected with theindicator on the instrument panel, and through the mechanical counter for thetotal display. Or remote display is mainly through The decelerated gear drivesthe permanent magnet to rotate so that the contacts of the spring relay (Hallsensor) are closed or opened synchronously at the same rotation frequency asthe permanent magnet, thereby sending one electric pulse to the other displayinstrument.

sandwich panels micro flow measurement
Item | model | K-factor | The minimum flow | Flow range | Connection size |
Gear flow meter | CX-G0.025-P-AL | 0.025ml | 0.001L/Min | 0.004~1 L/min | G1/8 |
gear flow meter | CX-G0.025-P-SS | 0.025ml | 0.001L/Min | 0.004~1 L/min | G1/8 |
gear flow meter | CX-G0.04-P-AL | 0.04ml | 0.004L/min | 0.01~2L/min | G1/4 |
gear flow meter | CX-G0.04-P-SS | 0.04ml | 0.004L/min | 0.01~2L/min | G1/4 |
gear flow meter | CX-G0.1-P-AL | 0.1ml | 0.008L/min | 0.02~4L/min | G3/8 |
gear flow meter | CX-G0.1-P-SS | 0.1ml | 0.008L/min | 0.02~4L/min | G3/8 |
gear flow meter | CX-G0.2-P-AL | 0.245ml | 0.01L/Min | 0.08~8L/min | G3/8 |
gear flow meter | CX-G0.2-P-SS | 0.245ml | 0.01L/Min | 0.08~8L/min | G3/8 |
gear flow meter | CX-G0.4-P-AL | 0.4ml | 0.01L/Min | 0.1~20L/min | G1/2 |
gear flow meter | CX-G0.4-P-SS | 0.4ml | 0.01L/Min | 0.1~20L/min | G1/2 |
gear flow meter | CX-G1-P-AL | 1ml | 0.02L/Min | 0.2~40L/min | G1/2 |
gear flow meter | CX-G1-P-SS | 1ml | 0.02L/Min | 0.2~40L/min | G1/2 |
gear flow meter | CX-G2-P-AL | 2ml | 0.04L/Min | 0.5-60L/min | G3/4 |
gear flow meter | CX-G2-P-SS | 2ml | 0.04L/Min | 0.5-60L/min | G3/4 |
Remark: Hightemperature, high pressure, high frequency, special connection, specialmaterials, two-way measurement, etc. can be customized
What are the precautions for the gear flow meter? Instrumentation expert tells mirco flow meter to clean the pipeline before installation. If the liquid contains solid particles, a filter must be installed upstream of the pipeline; if the gas is contained, the mirco flow meter should be installed without the requirement of a straight pipe section. It can be installed horizontally or vertically, if the direction is uncertain, we also Can be customized universal, such as the use of the robot arm. In general, ordinary flowmeter, if the measured viscosity or flow of the medium is too small, the general instrument is easy to leak, the accuracy can not be guaranteed, and this is precisely our advantage. Therefore, the base flow meter can meet the needs of most customers.