resin mini flow measurement
email: porter@microflowmeter.com Shanghai JSN Micro Flow Meter CO.,LTD is aprofessional manufacturer of super micro liquid flow meter, oval gear flowmeter , mass flow meter, spur gear flow meter, gear pump, gear metering pump,etc. industrial automation instrumentation design, manufacturing, sales andservice as one of the high-tech enterprises. The company has gathered manyoutstanding engineering and technical personnel, strong technical force,advanced production equipment, complete detection means, and developed a seriesof rigorous scientific production process. Sound quality assurance system, intheir own efforts and the vast majority of users with the strong support ofcontinuous development and expansion , Has achieved the recognition of theindustry, the products are exported to more than 20 provinces, municipalitiesand autonomous regions, and are widely used in electric power, metallurgy,chemical industry, military industry, oil fields, aviation and other fields.

resin mini flow measurement
Ovalgear flow meter is widely used inpetroleum, chemical and hydraulic industries due to its advantages of highprecision, simple installation, stable performance and goodrepeatability.However, the Oval gear flow meter that can be produceddomestically can only be applied due to the impatience of high pressure In thelow pressure occasion, the high pressure measurement occasion can only rely onthe foreign imported high pressure flowmeter.Therefore, the research of thehigh pressure Oval gear flow meter will help to expand the domestic applicationof the Oval gear flow meter and promote the development of the domestic flowmeasurement. Deep instrumentation independent research and development of the Ovalgear flow meter pressure up to 1000bar, it can be said has reached a higherlevel in the world, and obtain measurement certificate.
Oval gear flow meter, belonging to a type of volumetric flowmeter,cylindrical shape, with import and export, according to the media with a customfilter. Small size, light weight, easy installation, compact structure, withouttoo much maintenance; other The range ratio is very wide, generally more than1: 100, the minimum flow rate can be measured to 0.3ml / min; and thelinearization accuracy can reach 0.5% FS of full scale, so the use is very wideand can be used for measuring, regulating, controlling and distributing Highand low viscosity, or corrosive liquids, and there are health-type,explosion-proof for a special environment.

resin mini flow measurement
The Ovalgear flow meter is a volumetric flow meter. The metering chamber is composed ofupper and lower end caps. The shell is formed by an oval gear rotor. The gearrotor meshes with the rotating shaft to convey the fluid. The permanent magnetarranged in the rotor is used for the detection of the rotor rotation. Twosensor holes are placed on the upper end to cover the detection sensor. Asealing ring is installed between the housing and the upper and lower end capsto prevent leakage of the measurement fluid. The base depth flowmeter is madeof a material with high wear resistance so that the flowmeter Can guaranteehigh precision measurement within the long service life.

resin mini flow measurement
Technicaldata of CX-M Series micro oval Oval gear flow meter
Model | Flow range | Accuracy | Connection size |
CX-M2 | 0.5~150ml/min | 0.5% | G1/8" |
CX-M3 | 3~300ml/min | 0.5% | G1/8" |
CX-M5 | 5~1000ml/min | 0.5% | G1/8" |
CX-M6 | 0.5~100L/H | 0.5% | G1/4" |
CX-M9 | 6~600L/H | 0.5% | G1/4" |
CX-M12 | 0.3~30L/Min | 0.5% | G1/2" |
CX-M25 | 0.5~100L/Min | 0.5% | G1" |
Commonfault causes, troubleshooting
a. Thegear does not rotate: The gear is jammed by debris, the gear and cavity need tobe cleaned, and the filter is cleaned or replaced.
b. Thesmall flow error is too large: The flowmeter is installed in the wrongdirection, the best position goes up and down, or there are impurities to blockthe gear and need to be cleaned.
c. Theflow error is too large: The actual use flow range is less than or far greaterthan the flowmeter range. The corresponding flowmeter must be selected.
d. Noflow sensor signal: The gear is stuck or the circuit is connected incorrectlyor the circuit is damaged. The gear and cavity must be cleaned, or the circuitmust be correctly connected or replaced.