process control mini flowmeter
email: porter@microflowmeter.com Our company specialized in producing:super micro flow meter,oval gear flow meter ,mass flow meter,spur gear flow meter,gera pump,gear metering pump etc. The business covers the whole country and 70% of the instruments are exported to over 80 foreign countries. The company has always been based on sincerity and pragmatic, harmonious and inclusive as the company philosophy, committed to providing users with high-quality, high-precision flow meters. Quality and service is our company"s commitment to users The company has served for many years in the major oil fields, petrochemical groups, chemical companies, etc., has a wealth of practical experience. Flowmeter contains a number of technical patents. The technology has reached the national advanced level. And passed the China Quality Certification Center (CQC) ISO9001: 2008 certification.

process control mini flowmeter
At presentdomestic Oval gear flow meter structure is complex, bulky, bulky, noisy, smallscale, not suitable for low viscosity liquid, the market is more common withDTO series and OGM series. For these problems the country has been unable toovercome, while the Shanghai JiShen instrument Instrument company oval gear Ovalgear flow meter does not have the above problems, such as the same DN25caliber, our model CX-M25-AL, flow range: 0.5 ~ 100L / M, range of 1: 200 orhigher, and weighs only 1.5KG , While the DTO-25, the flow of 600-6000L / H,range ratio of only 1:10, the weight of up to 23KG. All this due totechnological breakthroughs, our chief engineer Tu workers, he is a formerSiemens senior engineer, the use of equipment It is also Siemens CNC MachiningCenter with cutting accuracy up to 0.001mm, which ensures that we produce highquality flow meters.
Shanghai JSN Micro Flow Meter Co., Ltd. is the second manufacturer ofmicro Oval gear flow meter in China. It is developed by Tu engineer (formerSiemens senior engineer) with independent intellectual property rights. Theproduction and processing equipment fully adopts Siemens CNC machining centerto ensure the minimum flow 0.1ml / min, which is rare in the world, theaccuracy of over 90% of peers. We can do more temperature 200C, the pressurecan be customized to 1000bar, many customers use it, but also unbelievable.Also domestic Most of the flowmeter use a year after the new calibration, butthe base depth meter after hundreds of conditions of medium test, the servicelife of more than 8 years, and without secondary calibration, since theestablishment of the base depth instrument Instrument determined to beworld-class flow meter, breaking the monopoly of international brands in themirco flow meter industry, so that customers can buy in the country realGerman-made quality flow meter.

process control mini flowmeter
The Ovalgear flow meter is a volumetric flow meter. The metering chamber is composed ofupper and lower end caps. The shell is formed by an oval gear rotor. The gearrotor meshes with the rotating shaft to convey the fluid. The permanent magnetarranged in the rotor is used for the detection of the rotor rotation. Twosensor holes are placed on the upper end to cover the detection sensor. Asealing ring is installed between the housing and the upper and lower end capsto prevent leakage of the measurement fluid. The base depth flowmeter is madeof a material with high wear resistance so that the flowmeter Can guaranteehigh precision measurement within the long service life.

process control mini flowmeter
Technicaldata of Gear type flow meter
Model | K-factor | Minimum flow | Flow range | Accuracy |
G0.025 | 0.025ml | 0.001L/Min | 0.008~2L/Min | 0.5% |
G0.04 | 0.04ml | 0.004L/Min | 0.2~4 L/min | 0.5% |
G0.1 | 0.4ml | 0.008L/Min | 0.01~8L/min | 0.5% |
G0.2 | 0.245ml | 0.01L/Min | 0.16~16 L/min | 0.5% |
G0.4 | 0.4ml | 0.01L/Min | 0.16~16 L/min | 0.5% |
G1 | 1.036ml | 0.02L/Min | 0.4~80 L/min | 0.5% |
What are the precautions for the gear flow meter?
1) In the field installation, it should be noted that the direction of the arrow on the flow meter housing is consistent with the flow direction of the fluid;
2) The flowmeter is installed on the same pipe with the same nominal internal diameter as the inlet and outlet fittings. When the pipe is connected with the flowmeter, the seal should not protrude into the fluid;
3) The fluid to be measured shall be filled with the metering room of the flowmeter and the connecting pipes before and after it. If the fluid to be measured contains gas, a gas separator shall be installed before the flowmeter and the filter;