[email protected] Shanghai JSNMicro Flow Meter CO.,LTD. is a family company and we are specialized in thereaserch and production of flow meters. These are our main products: mirco flow meter,oval gear flow meter ,coriolismass flow meter,electromagnetic flow meter,piston flow meter,spur gear flowmeter,gear pump,gear metering pump. In order to guarantee the after-sellservices, we cancled our agency and keep close contact with our client andmarket of flow meters. Our flow meter has reached the first class quality inthe world. Due to our advanced technology, we can customize for our clientaccording to different application and we can guarantee the fast delivery timeand it is usually within 2 weeks. Our applications include Metering technology,hydraulic or monitoring technology, filling, gluing, or mixing of various industrialsectors ,polyurethanes, chemicals, pharmaceuticals, paints and coatings,processing plants in the hydraulic and automotive industries, and Two-componenttechnology.

precision dosing micro flow measurement
Onceupon a time, China"s manufacturing industry in the world"s processing plant hasalways been the "low quality" representative of the world. Inparticular, the Oval gear flow meter for automatic process control has theadvantages of large volume, large noise, small turndown ratio, , The use ofeasy to leak, instability and so on, leaving customers a headache is that manyproblems in the early stages of product does not appear, and in the event ofafter-sale is very troublesome, bothering money, these are domestic objectiveobjective existence of Oval gear flow meter Therefore, users buy Oval gear flowmeter is like buying lottery tickets, do not know sent to the installation siteOval gear flow meter is a blessing, in a sense, is a matter of course, whilethe base depth meter appeared to solve these problems in one fell swoop.
TheCX-M and G-series mirco flow meters are the world"s new volumetric flowmetersintroduced by BASF in 2011. Since its establishment, the CX-M oval gear flowmeter and the G-series mirco flow meters have been selling well in the marketfor more than 100,000 units a year since they were sold. The third generationlaunched in 2017, with more than 90% accuracy and stability, won thecertification of the National Bureau of Metrology. The quality and reliabilityof Shanghai JiShen instruments need not worry. According to the statistics ofChina Instrument Association, Deep flow meter reliability has always beenranked in the top 3, especially in the long-term statistics failure rate is farbelow the industry average, deep advocate "the best after-sales service isno service", but also achieved a continuous three years without qualitycomplaints .

precision dosing micro flow measurement
The Ovalgear flow meter is a volumetric flow meter that consists of a flow chamber in achamber and one or several elements that are rotated by fluid flow to form aflow meter. Leakage between the rotating element and the inner wall and theselected working range The internal flow rate is negligible. The rotation ofthe element is transmitted mechanically or by other means to the indicatingdevice to indicate the volume flow of the fluid flowing through.

precision dosing micro flow measurement
Technicaldata of CX-M Series micro oval Oval gear flow meter
Model | Flow range | Accuracy | Connection size |
CX-M2 | 0.5~150ml/min | 0.5% | G1/8" |
CX-M3 | 3~300ml/min | 0.5% | G1/8" |
CX-M5 | 5~1000ml/min | 0.5% | G1/8" |
CX-M6 | 0.5~100L/H | 0.5% | G1/4" |
CX-M9 | 6~600L/H | 0.5% | G1/4" |
CX-M12 | 0.3~30L/Min | 0.5% | G1/2" |
CX-M25 | 0.5~100L/Min | 0.5% | G1" |
What are the precautions for the gear flow meter?
1) In the field installation, it should be noted that the direction of the arrow on the flow meter housing is consistent with the flow direction of the fluid;
2) The flowmeter is installed on the same pipe with the same nominal internal diameter as the inlet and outlet fittings. When the pipe is connected with the flowmeter, the seal should not protrude into the fluid;
3) The fluid to be measured shall be filled with the metering room of the flowmeter and the connecting pipes before and after it. If the fluid to be measured contains gas, a gas separator shall be installed before the flowmeter and the filter;