precision dosing gear flow sensor
email: porter@microflowmeter.com Shanghai JSNMicro Flow Meter CO.,LTD was founded in 2011 and it was a family company whichhas more than 30 years history. Through about 30 years accumulate of technologywe have gained many certificates and national invention certificates andreached the leading technology level. For example, the measuring range ratio ofnormal flow meters is usual 1:10, but we can make the ratio to be 1:200 or1:1000. We can make the flow meter stand 200C and 1000bar high pressure. Thisis owe to former Siemens engineer Mr Stone and his high accurate CNC machiningcenter, and we have been the benchmarking in this line. Main of productsare: super mirco flow meter,oval gearflow meter ,coriolis mass flow meter,electromagnetic flow meter,piston flowmeter,spur gear flow meter,gear pump,gear metering pump.

precision dosing gear flow sensor
Onceupon a time, China"s manufacturing industry in the world"s processing plant hasalways been the "low quality" representative of the world. Inparticular, the Oval gear flow meter for automatic process control has theadvantages of large volume, large noise, small turndown ratio, , The use ofeasy to leak, instability and so on, leaving customers a headache is that manyproblems in the early stages of product does not appear, and in the event ofafter-sale is very troublesome, bothering money, these are domestic objectiveobjective existence of Oval gear flow meter Therefore, users buy Oval gear flowmeter is like buying lottery tickets, do not know sent to the installation siteOval gear flow meter is a blessing, in a sense, is a matter of course, whilethe base depth meter appeared to solve these problems in one fell swoop.
A newgeneration of deep base Oval gear flow meter has been officially listed on thenational market in early 2017. This is a newly developed volumetric flowmeteror a positive displacement flowmeter developed by QWEN engineers combiningadvanced technologies both at home and abroad. Deep base of the exhibitionhall, will see the flow meters on behalf of the generation (such as DTO, CX-FM,CX-M, CX-G series), also see the base depth meter in the continuoustechnological innovation. Is characterized by small flow, a large range, highprecision, long life. Through several iterations, the quality of the product isgetting higher and higher, while the price is less than one-third of the importedbrands, can be said that the Shanghai base deep mirco flow meter Successfuldevelopment, domestic customers do not have to worry about delivery, sale andother issues.

precision dosing gear flow sensor
Ovalgear flow meter Through the rotation of the gear cavity, through a series ofdeceleration and speed ratio adjustment mechanism, directly connected with theindicator on the instrument panel, and through the mechanical counter for thetotal display. Or remote display is mainly through The decelerated gear drivesthe permanent magnet to rotate so that the contacts of the spring relay (Hallsensor) are closed or opened synchronously at the same rotation frequency asthe permanent magnet, thereby sending one electric pulse to the other displayinstrument.

precision dosing gear flow sensor
Maintechnical data of JSN micro oval Oval gear flow meter
CX-M2,flow range :0.5~150ml/min,accuracy 0.5%,G1/8"
CX-M3, flowrange:3~300ml/min,accuracy 0.5%,G1/8"
CX-M5, flowrange:5~1000ml/min,accuracy 0.5%,G1/8"
CX-M6, flowrange:0.5~100L/H,accuracy 0.5%,G1/4"
CX-M9, flowrange:6~600L/H,accuracy 0.5%,G1/4"
CX-M12,flow range:0.3~30L/Min, accuracy 0.5%,G1/2"
CX-M25,flow range:0.5~100L/Min, accuracy 0.5%,G1"
a. Thegear does not rotate: The gear is jammed by debris, the gear and cavity need tobe cleaned, and the filter is cleaned or replaced.
b. Thesmall flow error is too large: The flowmeter is installed in the wrongdirection, the best position goes up and down, or there are impurities to blockthe gear and need to be cleaned.
c. Theflow error is too large: The actual use flow range is less than or far greaterthan the flowmeter range. The corresponding flowmeter must be selected.
d. Noflow sensor signal: The gear is stuck or the circuit is connected incorrectlyor the circuit is damaged. The gear and cavity must be cleaned, or the circuitmust be correctly connected or replaced.