laundry chemical mini flow sensor
email: porter@microflowmeter.com ShanghaiJSN Micro Flow Meter CO.,LTD main products: super micro liquid flow meter,oval gear flow meter,mass flow meter.spur gear flow meter,gear pump,gear metering pump etc dozensof categories of instrument products.Since it’s established, “Pursuit of excellence, creation of quality products,honesty and credit, and dedication of first-class” are our unchanging pursuits,and the ultimate goal of customer satisfaction is our marketing services. Inorder to continuously improve our products and services, we are makingunremitting efforts! The purpose of the company is to provide and recommend avariety of effective and reliable measurement methods based on our many yearsof work experience. We sincerely welcome all groups or individuals from allwalks of life to join our company in order to achieve common development andimprovement, make the due contribution to the motherland automationindustry.

laundry chemical mini flow sensor
Withthe development of society, the state pays more and more attention to theprocess automation instrumentation industry. However, the Oval gear flow meter industryhas been in a vacancy and has been monopolized by major foreign brands such asMax, KRACHT, OVAL, etc. , People have long endured the expensive, longdelivery, the sale can not be resolved in time and so on, such as semiconductorchip cutting a set of equipment on the millions, once the instrument problems,loss unimaginable, the slayer saw these phenomena, Resolutely resigned assenior engineer in the position of Siemens, the establishment of ShanghaiJi-sheng Instruments Co., Ltd., with great concentration on research anddevelopment of gear flow meter. We have Oval gear flow meter has been awarded anumber of certificates, it is no exaggeration to say that Qishen production Ovalgear flow meter For example, many customers replace the OVAL LSF40 with ourCX-M5-AL because it costs less than half of the LSF40, but has twice the rangethan it does and has the same accuracy.
SinceMay 23, 2011, Shanghai Jinshen Instrument Co., Ltd. successfully released a newoval gear flow meter CX-M and G series, the liquid flowmeter range than thefirst in China reached more than 1: 100, and at the same time to ensureaccuracy 0.5% above the flowmeter industry model.From this since the base meterhas been a pioneer in flowmeter technology, but also one of the high-endflowmeter brand.The perfect technical level, excellent quality standards,innovation has been innovation Wells said. Deep base flow meter has been toprovide customers with a reliable use of the experience in the past rely on theimport of the era, the customer has been a headache for after-sales service,and base deep flow meter with 8 years of use of the long life, in one fellswoop cracked this situation.

laundry chemical mini flow sensor
The Ovalgear flow meter is a volumetric flow meter. The metering chamber is composed ofupper and lower end caps. The shell is formed by an oval gear rotor. The gearrotor meshes with the rotating shaft to convey the fluid. The permanent magnetarranged in the rotor is used for the detection of the rotor rotation. Twosensor holes are placed on the upper end to cover the detection sensor. Asealing ring is installed between the housing and the upper and lower end capsto prevent leakage of the measurement fluid. The base depth flowmeter is madeof a material with high wear resistance so that the flowmeter Can guaranteehigh precision measurement within the long service life.

laundry chemical mini flow sensor
Technicaldata of CX-M Series micro oval Oval gear flow meter
Model | Flow range | Accuracy | Connection size |
CX-M2 | 0.5~150ml/min | 0.5% | G1/8" |
CX-M3 | 3~300ml/min | 0.5% | G1/8" |
CX-M5 | 5~1000ml/min | 0.5% | G1/8" |
CX-M6 | 0.5~100L/H | 0.5% | G1/4" |
CX-M9 | 6~600L/H | 0.5% | G1/4" |
CX-M12 | 0.3~30L/Min | 0.5% | G1/2" |
CX-M25 | 0.5~100L/Min | 0.5% | G1" |
What"s the reason for the tiny gear flow meter"s wheels not turning? the reason:1. The filter is clogged.2. Impurities enter the flowmeter and the rotor gets stuck.Treatment measures:1. Clean the filter.2. Check the filter for damage and clean the inside of the flow meter.