isocyanate mini flow meter
email: porter@microflowmeter.com Shanghai JSNMicro Flow Meter CO.,LTD was founded in 2011 and it was a family company whichhas more than 30 years history. Through about 30 years accumulate of technologywe have gained many certificates and national invention certificates andreached the leading technology level. For example, the measuring range ratio ofnormal flow meters is usual 1:10, but we can make the ratio to be 1:200 or1:1000. We can make the flow meter stand 200C and 1000bar high pressure. Thisis owe to former Siemens engineer Mr Stone and his high accurate CNC machiningcenter, and we have been the benchmarking in this line. Main of productsare: super mirco flow meter,oval gearflow meter ,coriolis mass flow meter,electromagnetic flow meter,piston flowmeter,spur gear flow meter,gear pump,gear metering pump.

isocyanate mini flow meter
Withthe development of society, the state pays more and more attention to theprocess automation instrumentation industry. However, the Oval gear flow meter industryhas been in a vacancy and has been monopolized by major foreign brands such asMax, KRACHT, OVAL, etc. , People have long endured the expensive, longdelivery, the sale can not be resolved in time and so on, such as semiconductorchip cutting a set of equipment on the millions, once the instrument problems,loss unimaginable, the slayer saw these phenomena, Resolutely resigned assenior engineer in the position of Siemens, the establishment of ShanghaiJi-sheng Instruments Co., Ltd., with great concentration on research anddevelopment of gear flow meter. We have Oval gear flow meter has been awarded anumber of certificates, it is no exaggeration to say that Qishen production Ovalgear flow meter For example, many customers replace the OVAL LSF40 with ourCX-M5-AL because it costs less than half of the LSF40, but has twice the rangethan it does and has the same accuracy.
Whymany customers gradually from the major international brands MAX, OVAL Obar,KRACHT Clarke and other gradually purchased base deep Oval gear flow meter it?Many customers also have questions: why base depth can be reported Oval gearflow meter so good? This stems from our engineers is a former Siemens seniorengineer, the device is also fully adopted Siemens CNC machining center, thecutting height of 0.001mm, to ensure that our flowmeters minimum flow meter canbe measured to 0.1ml / min, which are at home and abroad are Rare, the currentproducts have been awarded the national measurement certificate, and ISO, SGS,CE, after thousands of customers hundreds of conditions medium test, once againwe are very grateful to the recognition of domestic and foreign customers.Attitude, carrying domestic and foreign customers look forward to working hardto make real benchmarking business.

isocyanate mini flow meter
The ovalgear flow meter"s metering principle is the same as that of a generalvolumetric flow meter. The gears mesh with the fluid to be transported. Thefluid to be measured enters the chamber through the oil inlet and pushes therotor so that the fluid is continuously divided into the same volume of fluid.Oil port output. For every one rotation of the rotor, the flowmeter outputs thesame volume of fluid in the four metering chambers in the figure. By measuringthe number of revolutions of the elliptical gear rotor, the volume flow throughthe fluid can be obtained.

isocyanate mini flow meter
Maintechnical data of JSN micro oval Oval gear flow meter
CX-M2,flow range :0.5~150ml/min,accuracy 0.5%,G1/8"
CX-M3, flowrange:3~300ml/min,accuracy 0.5%,G1/8"
CX-M5, flowrange:5~1000ml/min,accuracy 0.5%,G1/8"
CX-M6, flowrange:0.5~100L/H,accuracy 0.5%,G1/4"
CX-M9, flowrange:6~600L/H,accuracy 0.5%,G1/4"
CX-M12,flow range:0.3~30L/Min, accuracy 0.5%,G1/2"
CX-M25,flow range:0.5~100L/Min, accuracy 0.5%,G1"
What is the reason why the tiny gauge flow meter is larger than the actual value? the reason:1. The flow has a large pulse.2. The medium is mixed with gas.3. Medium viscosity is too large.Treatment measures:1. Reduce the pulsation of the flow in the pipeline.2. Install degasifier.3. Recalibrate, replace the adjustment gear pair and correct it.