新闻资讯PCBanner 新闻资讯wapBanner
首页 > Flow Meters' Diary > News of Flow Meter > hydraulic system micro flow sensor
Submit a message
  • Name*
  • Tel*
  • Email*
  • Content*
  •  

Friendship tips

    Shanghai JSN Micro Flow Meter CO.,LTD as a high-tech industrial products manufacturing and complete sets of product sales, R & D, production, processing and sales as one, with independent import and export rights of enterprises.
    The company's main flow meter, level meter, and pressure controller, temperature controller, analytical instruments and other various types of instrumentation. To solve all kinds of problems, and provide complete sales service for customers with professional technical point of view.
International service telephone
(86)021-57632436

hydraulic system micro flow sensor

Date:2017-02-01 source:
  hydraulic system micro flow sensor  

email: porter@microflowmeter.com  Shanghai JSN Micro Flow Meter CO.,LTD is located inthe Shanghai Songjiang industry zone, which is a famous enterprice forresearch,produce,sales and service of flow meter, registered capital of 11million RMB. Main products:mirco flow meter,oval gear flow meter  ,piston flow meter,gear flow meter,gearpump,mass flow meter. Products with superior performance, excellent qualityhas been the various professional certification and customer recognition. Thecompany has a number of fluid measurement equipment experts and various typesof senior engineer, continuous development and manufacturing, upgradingproducts are available every year.

 hydraulic system micro flow sensor

hydraulic system micro flow sensor

Ovalgear flow meter  is widely used inpetroleum, chemical and hydraulic industries due to its advantages of highprecision, simple installation, stable performance and goodrepeatability.However, the Oval gear flow meter that can be produceddomestically can only be applied due to the impatience of high pressure In thelow pressure occasion, the high pressure measurement occasion can only rely onthe foreign imported high pressure flowmeter.Therefore, the research of thehigh pressure Oval gear flow meter will help to expand the domestic applicationof the Oval gear flow meter and promote the development of the domestic flowmeasurement. Deep instrumentation independent research and development of the Ovalgear flow meter pressure up to 1000bar, it can be said has reached a higherlevel in the world, and obtain measurement certificate.

Oval gear flow meter, belonging to a type of volumetric flowmeter,cylindrical shape, with import and export, according to the media with a customfilter. Small size, light weight, easy installation, compact structure, withouttoo much maintenance; other The range ratio is very wide, generally more than1: 100, the minimum flow rate can be measured to 0.3ml / min; and thelinearization accuracy can reach 0.5% FS of full scale, so the use is very wideand can be used for measuring, regulating, controlling and distributing Highand low viscosity, or corrosive liquids, and there are health-type,explosion-proof for a special environment.

micro flow sensor

hydraulic system micro flow sensor

The Ovalgear flow meter is a volumetric flow meter that consists of a flow chamber in achamber and one or several elements that are rotated by fluid flow to form aflow meter. Leakage between the rotating element and the inner wall and theselected working range The internal flow rate is negligible. The rotation ofthe element is transmitted mechanically or by other means to the indicatingdevice to indicate the volume flow of the fluid flowing through.

 hydraulic system micro flow sensor

hydraulic system micro flow sensor

Technicaldata of CX-M Series micro oval Oval gear flow meter

Model

Flow  range

Accuracy

Connection  size

CX-M2

0.5~150ml/min

0.5%

G1/8"

CX-M3

3~300ml/min

0.5%

G1/8"

CX-M5

5~1000ml/min

0.5%

G1/8"

CX-M6

0.5~100L/H

0.5%

G1/4"

CX-M9

6~600L/H

0.5%

G1/4"

CX-M12

0.3~30L/Min

0.5%

G1/2"

CX-M25

0.5~100L/Min

0.5%

G1"


What are the precautions for the gear flow meter?

1) When the flow exceeds the specified maximum flow rate, the Oval gear flow meter wear increases with the increase of the rotation speed, and the pressure loss increases sharply, should be avoided. Less than the minimum flow, although still able to measure, but the error increases. Flow meter The starting flow is about 2% of the maximum flow, and the normal working flow is preferably 70%-80% of the maximum flow.

2) Deep-rooted flowmeter is used with various viscosity media from 0.3 ~ 100000cps, different viscosity media will affect the range, the following single must be noted

3) The measured liquid temperature should not exceed the specified value, otherwise, the instrument can not work properly, or even stuck, the counter part is easily damaged at high temperatures. Liquid temperature changes will also cause additional errors in viscosity.

Share to:


© 2016 Shanghai JSN Micro Flow Meter CO.,LTD  All rights reserved  Shanghai ICP preparation 07036704-1Map | Contact