email: porter@microflowmeter.com Shanghai JSNMicro Flow Meter CO.,LTD. is a family company and we are specialized in thereaserch and production of flow meters. These are our main products: mirco flow meter,oval gear flow meter ,coriolismass flow meter,electromagnetic flow meter,piston flow meter,spur gear flowmeter,gear pump,gear metering pump. In order to guarantee the after-sellservices, we cancled our agency and keep close contact with our client andmarket of flow meters. Our flow meter has reached the first class quality inthe world. Due to our advanced technology, we can customize for our clientaccording to different application and we can guarantee the fast delivery timeand it is usually within 2 weeks. Our applications include Metering technology,hydraulic or monitoring technology, filling, gluing, or mixing of various industrialsectors ,polyurethanes, chemicals, pharmaceuticals, paints and coatings,processing plants in the hydraulic and automotive industries, and Two-componenttechnology.

hydraulic oil micro flow meter
Ovalgear flow meter is widely used inpetroleum, chemical and hydraulic industries due to its advantages of highprecision, simple installation, stable performance and goodrepeatability.However, the Oval gear flow meter that can be produceddomestically can only be applied due to the impatience of high pressure In thelow pressure occasion, the high pressure measurement occasion can only rely onthe foreign imported high pressure flowmeter.Therefore, the research of thehigh pressure Oval gear flow meter will help to expand the domestic applicationof the Oval gear flow meter and promote the development of the domestic flowmeasurement. Deep instrumentation independent research and development of the Ovalgear flow meter pressure up to 1000bar, it can be said has reached a higherlevel in the world, and obtain measurement certificate.
Oval gear flow meter, belonging to a type of volumetric flowmeter,cylindrical shape, with import and export, according to the media with a customfilter. Small size, light weight, easy installation, compact structure, withouttoo much maintenance; other The range ratio is very wide, generally more than1: 100, the minimum flow rate can be measured to 0.3ml / min; and thelinearization accuracy can reach 0.5% FS of full scale, so the use is very wideand can be used for measuring, regulating, controlling and distributing Highand low viscosity, or corrosive liquids, and there are health-type,explosion-proof for a special environment.

hydraulic oil micro flow meter
The Ovalgear flow meter is a volumetric flow meter. The metering chamber is composed ofupper and lower end caps. The shell is formed by an oval gear rotor. The gearrotor meshes with the rotating shaft to convey the fluid. The permanent magnetarranged in the rotor is used for the detection of the rotor rotation. Twosensor holes are placed on the upper end to cover the detection sensor. Asealing ring is installed between the housing and the upper and lower end capsto prevent leakage of the measurement fluid. The base depth flowmeter is madeof a material with high wear resistance so that the flowmeter Can guaranteehigh precision measurement within the long service life.

hydraulic oil micro flow meter
Technicaldata of Gear type flow meter
Model | K-factor | Minimum flow | Flow range | Accuracy |
G0.025 | 0.025ml | 0.001L/Min | 0.008~2L/Min | 0.5% |
G0.04 | 0.04ml | 0.004L/Min | 0.2~4 L/min | 0.5% |
G0.1 | 0.4ml | 0.008L/Min | 0.01~8L/min | 0.5% |
G0.2 | 0.245ml | 0.01L/Min | 0.16~16 L/min | 0.5% |
G0.4 | 0.4ml | 0.01L/Min | 0.16~16 L/min | 0.5% |
G1 | 1.036ml | 0.02L/Min | 0.4~80 L/min | 0.5% |
What"s the reason for the tiny gear flow meter"s wheels not turning? the reason:1. The filter is clogged.2. Impurities enter the flowmeter and the rotor gets stuck.Treatment measures:1. Clean the filter.2. Check the filter for damage and clean the inside of the flow meter.