high viscosity micro flow measurement
email: porter@microflowmeter.com Shanghai JSNMicro Flow Meter CO.,LTD was founded in 2011 by Mr Stone and it was a familycompany which has more than 30 years history. We are specialized in highquality, high accuracym high frequence , temperature and wide measuring rangeflow measuring and detecting equipment. We strictly enforce ISO9001 standard.Our main produsts are: super mirco flow meter,oval gear flow meter ,coriolismass flow meter,electromagnetic flow meter,piston flow meter,spur gear flowmeter,gear pump,gear metering pump. Our micro flow meter can replace Kracht, OVAL,SIKA and OMAGE foreign brands and so on. Our flow meters are mainly used forwater treatment, oil, food, grease industries; chemical,ink, pharmacy, petroleum,cars; glue , polyurethaneand electrolyte and additives and other industries.

high viscosity micro flow measurement
Onceupon a time, China"s manufacturing industry in the world"s processing plant hasalways been the "low quality" representative of the world. Inparticular, the Oval gear flow meter for automatic process control has theadvantages of large volume, large noise, small turndown ratio, , The use ofeasy to leak, instability and so on, leaving customers a headache is that manyproblems in the early stages of product does not appear, and in the event ofafter-sale is very troublesome, bothering money, these are domestic objectiveobjective existence of Oval gear flow meter Therefore, users buy Oval gear flowmeter is like buying lottery tickets, do not know sent to the installation siteOval gear flow meter is a blessing, in a sense, is a matter of course, whilethe base depth meter appeared to solve these problems in one fell swoop.
Oval gear flow meter, belonging to a type of volumetric flowmeter,cylindrical shape, with import and export, according to the media with a customfilter. Small size, light weight, easy installation, compact structure, withouttoo much maintenance; other The range ratio is very wide, generally more than1: 100, the minimum flow rate can be measured to 0.3ml / min; and thelinearization accuracy can reach 0.5% FS of full scale, so the use is very wideand can be used for measuring, regulating, controlling and distributing Highand low viscosity, or corrosive liquids, and there are health-type,explosion-proof for a special environment.

high viscosity micro flow measurement
The Ovalgear flow meter is a volumetric flow meter. The metering chamber is composed ofupper and lower end caps. The shell is formed by an oval gear rotor. The gearrotor meshes with the rotating shaft to convey the fluid. The permanent magnetarranged in the rotor is used for the detection of the rotor rotation. Twosensor holes are placed on the upper end to cover the detection sensor. Asealing ring is installed between the housing and the upper and lower end capsto prevent leakage of the measurement fluid. The base depth flowmeter is madeof a material with high wear resistance so that the flowmeter Can guaranteehigh precision measurement within the long service life.

high viscosity micro flow measurement
Item | model | K-factor | The minimum flow | Flow range | Connection size |
Gear flow meter | CX-G0.025-P-AL | 0.025ml | 0.001L/Min | 0.004~1 L/min | G1/8 |
gear flow meter | CX-G0.025-P-SS | 0.025ml | 0.001L/Min | 0.004~1 L/min | G1/8 |
gear flow meter | CX-G0.04-P-AL | 0.04ml | 0.004L/min | 0.01~2L/min | G1/4 |
gear flow meter | CX-G0.04-P-SS | 0.04ml | 0.004L/min | 0.01~2L/min | G1/4 |
gear flow meter | CX-G0.1-P-AL | 0.1ml | 0.008L/min | 0.02~4L/min | G3/8 |
gear flow meter | CX-G0.1-P-SS | 0.1ml | 0.008L/min | 0.02~4L/min | G3/8 |
gear flow meter | CX-G0.2-P-AL | 0.245ml | 0.01L/Min | 0.08~8L/min | G3/8 |
gear flow meter | CX-G0.2-P-SS | 0.245ml | 0.01L/Min | 0.08~8L/min | G3/8 |
gear flow meter | CX-G0.4-P-AL | 0.4ml | 0.01L/Min | 0.1~20L/min | G1/2 |
gear flow meter | CX-G0.4-P-SS | 0.4ml | 0.01L/Min | 0.1~20L/min | G1/2 |
gear flow meter | CX-G1-P-AL | 1ml | 0.02L/Min | 0.2~40L/min | G1/2 |
gear flow meter | CX-G1-P-SS | 1ml | 0.02L/Min | 0.2~40L/min | G1/2 |
gear flow meter | CX-G2-P-AL | 2ml | 0.04L/Min | 0.5-60L/min | G3/4 |
gear flow meter | CX-G2-P-SS | 2ml | 0.04L/Min | 0.5-60L/min | G3/4 |
Remark: Hightemperature, high pressure, high frequency, special connection, specialmaterials, two-way measurement, etc. can be customized
Commonfault causes, troubleshooting
a. Thegear does not rotate: The gear is jammed by debris, the gear and cavity need tobe cleaned, and the filter is cleaned or replaced.
b. Thesmall flow error is too large: The flowmeter is installed in the wrongdirection, the best position goes up and down, or there are impurities to blockthe gear and need to be cleaned.
c. Theflow error is too large: The actual use flow range is less than or far greaterthan the flowmeter range. The corresponding flowmeter must be selected.
d. Noflow sensor signal: The gear is stuck or the circuit is connected incorrectlyor the circuit is damaged. The gear and cavity must be cleaned, or the circuitmust be correctly connected or replaced.