    Shanghai JSN Micro Flow Meter CO.,LTD as a high-tech industrial products manufacturing and complete sets of product sales, R & D, production, processing and sales as one, with independent import and export rights of enterprises.
    The company's main flow meter, level meter, and pressure controller, temperature controller, analytical instruments and other various types of instrumentation. To solve all kinds of problems, and provide complete sales service for customers with professional technical point of view.
International service telephone
(86)021-57632436

fluid gear flow measurement

Date:2017-01-20 source:

  fluid gear flow measurement  

email: porter@microflowmeter.com  Shanghai JSN Micro Flow Meter CO.,LTD is theprofessional supplier for oval gear flow meter ,mass flow meter,electromagneticflow meter,micro flow meter,gear pump.The products are widely used for Petroleum,petrochemical, chemical, metallurgy, nuclear industry, environmentalprotection, electricity, national defense, medicine, food and other fields, andexported to foreign countries. The company was founded in 2011 by Siemens engineersand has advanced CNC machining centers in the country. Since its inception, thecompany has continued to profit, has developed steadily, has strong technicalequipment and human resources, and has provided a large number of high-qualitymetering products for various industries in the national economy.

 fluid gear flow measurement

fluid gear flow measurement

Withthe development of society, the state pays more and more attention to theprocess automation instrumentation industry. However, the Oval gear flow meter industryhas been in a vacancy and has been monopolized by major foreign brands such asMax, KRACHT, OVAL, etc. , People have long endured the expensive, longdelivery, the sale can not be resolved in time and so on, such as semiconductorchip cutting a set of equipment on the millions, once the instrument problems,loss unimaginable, the slayer saw these phenomena, Resolutely resigned assenior engineer in the position of Siemens, the establishment of ShanghaiJi-sheng Instruments Co., Ltd., with great concentration on research anddevelopment of gear flow meter. We have Oval gear flow meter has been awarded anumber of certificates, it is no exaggeration to say that Qishen production Ovalgear flow meter For example, many customers replace the OVAL LSF40 with ourCX-M5-AL because it costs less than half of the LSF40, but has twice the rangethan it does and has the same accuracy.

Whymany customers gradually from the major international brands MAX, OVAL Obar,KRACHT Clarke and other gradually purchased base deep Oval gear flow meter it?Many customers also have questions: why base depth can be reported Oval gearflow meter so good? This stems from our engineers is a former Siemens seniorengineer, the device is also fully adopted Siemens CNC machining center, thecutting height of 0.001mm, to ensure that our flowmeters minimum flow meter canbe measured to 0.1ml / min, which are at home and abroad are Rare, the currentproducts have been awarded the national measurement certificate, and ISO, SGS,CE, after thousands of customers hundreds of conditions medium test, once againwe are very grateful to the recognition of domestic and foreign customers.Attitude, carrying domestic and foreign customers look forward to working hardto make real benchmarking business.

gear flow measurement

fluid gear flow measurement

The ovalgear flow meter"s metering principle is the same as that of a generalvolumetric flow meter. The gears mesh with the fluid to be transported. Thefluid to be measured enters the chamber through the oil inlet and pushes therotor so that the fluid is continuously divided into the same volume of fluid.Oil port output. For every one rotation of the rotor, the flowmeter outputs thesame volume of fluid in the four metering chambers in the figure. By measuringthe number of revolutions of the elliptical gear rotor, the volume flow throughthe fluid can be obtained.

 fluid gear flow measurement

fluid gear flow measurement

Technicaldata of CX-M Series micro oval Oval gear flow meter

Model

Flow  range

Accuracy

Connection  size

CX-M2

0.5~150ml/min

0.5%

G1/8"

CX-M3

3~300ml/min

0.5%

G1/8"

CX-M5

5~1000ml/min

0.5%

G1/8"

CX-M6

0.5~100L/H

0.5%

G1/4"

CX-M9

6~600L/H

0.5%

G1/4"

CX-M12

0.3~30L/Min

0.5%

G1/2"

CX-M25

0.5~100L/Min

0.5%

G1"


What"s the reason for the tiny gear flow meter"s wheels not turning? the reason:1. The filter is clogged.2. Impurities enter the flowmeter and the rotor gets stuck.Treatment measures:1. Clean the filter.2. Check the filter for damage and clean the inside of the flow meter.