electrohydrodynamic mini flow sensor
email: porter@microflowmeter.com Shanghai JSN Micro Flow Meter CO.,LTD is a familyenterprise, has 30 years history. It’s established by engineer of Siemens. The production base is locatedin Shanghai Songjiang Hi-Tech Zone. The company has modernized standard factorybuildings and intelligent office buildings, professional gear flow meter andgear pump research department and the most advanced performance test bench inChina.Which imjnmnmnm s a research, development, production, sales, service inone, cross-country, cross-regional integrated enterprise. The company has aGerman high-end gear flow meter and gear pump production technology, has aninternational advanced management model and first-class Production equipment,specializing in the production of mirco flow meter, optional oval gear flowmeter , electromagnetic flow meter, mirco flow meter, piston flow meter, massflow meter, gear flow meter, gear pump and other products. Widely used in waterconservancy, construction, fire protection, Electricity, metallurgy, chemicalindustry, environmental protection, pharmaceuticals, food and other fields.

electrohydrodynamic mini flow sensor
At presentdomestic Oval gear flow meter structure is complex, bulky, bulky, noisy, smallscale, not suitable for low viscosity liquid, the market is more common withDTO series and OGM series. For these problems the country has been unable toovercome, while the Shanghai JiShen instrument Instrument company oval gear Ovalgear flow meter does not have the above problems, such as the same DN25caliber, our model CX-M25-AL, flow range: 0.5 ~ 100L / M, range of 1: 200 orhigher, and weighs only 1.5KG , While the DTO-25, the flow of 600-6000L / H,range ratio of only 1:10, the weight of up to 23KG. All this due totechnological breakthroughs, our chief engineer Tu workers, he is a formerSiemens senior engineer, the use of equipment It is also Siemens CNC MachiningCenter with cutting accuracy up to 0.001mm, which ensures that we produce highquality flow meters.
Shanghai JSN Micro Flow Meter Co., Ltd. is the second manufacturer ofmicro Oval gear flow meter in China. It is developed by Tu engineer (formerSiemens senior engineer) with independent intellectual property rights. Theproduction and processing equipment fully adopts Siemens CNC machining centerto ensure the minimum flow 0.1ml / min, which is rare in the world, theaccuracy of over 90% of peers. We can do more temperature 200C, the pressurecan be customized to 1000bar, many customers use it, but also unbelievable.Also domestic Most of the flowmeter use a year after the new calibration, butthe base depth meter after hundreds of conditions of medium test, the servicelife of more than 8 years, and without secondary calibration, since theestablishment of the base depth instrument Instrument determined to beworld-class flow meter, breaking the monopoly of international brands in themirco flow meter industry, so that customers can buy in the country realGerman-made quality flow meter.

electrohydrodynamic mini flow sensor
The Ovalgear flow meter is a volumetric flow meter that consists of a flow chamber in achamber and one or several elements that are rotated by fluid flow to form aflow meter. Leakage between the rotating element and the inner wall and theselected working range The internal flow rate is negligible. The rotation ofthe element is transmitted mechanically or by other means to the indicatingdevice to indicate the volume flow of the fluid flowing through.

electrohydrodynamic mini flow sensor
Technicaldata of CX-M Series micro oval Oval gear flow meter
Model | Flow range | Accuracy | Connection size |
CX-M2 | 0.5~150ml/min | 0.5% | G1/8" |
CX-M3 | 3~300ml/min | 0.5% | G1/8" |
CX-M5 | 5~1000ml/min | 0.5% | G1/8" |
CX-M6 | 0.5~100L/H | 0.5% | G1/4" |
CX-M9 | 6~600L/H | 0.5% | G1/4" |
CX-M12 | 0.3~30L/Min | 0.5% | G1/2" |
CX-M25 | 0.5~100L/Min | 0.5% | G1" |
Commonfault causes, troubleshooting
a. Thegear does not rotate: The gear is jammed by debris, the gear and cavity need tobe cleaned, and the filter is cleaned or replaced.
b. Thesmall flow error is too large: The flowmeter is installed in the wrongdirection, the best position goes up and down, or there are impurities to blockthe gear and need to be cleaned.
c. Theflow error is too large: The actual use flow range is less than or far greaterthan the flowmeter range. The corresponding flowmeter must be selected.
d. Noflow sensor signal: The gear is stuck or the circuit is connected incorrectlyor the circuit is damaged. The gear and cavity must be cleaned, or the circuitmust be correctly connected or replaced.