    Shanghai JSN Micro Flow Meter CO.,LTD as a high-tech industrial products manufacturing and complete sets of product sales, R & D, production, processing and sales as one, with independent import and export rights of enterprises.
    The company's main flow meter, level meter, and pressure controller, temperature controller, analytical instruments and other various types of instrumentation. To solve all kinds of problems, and provide complete sales service for customers with professional technical point of view.
International service telephone
(86)021-57632436

closed-loop management gear flow measurement

Date:2017-01-20 source:

  closed-loop management gear flow measurement  

email: porter@microflowmeter.com  Shanghai JSNMicro Flow Meter CO.,LTD has a high-tech talent team who have long been engagedin the design, development, installation and commissioning of automatic controlresearch, and have provided satisfactory sets of systems for variousindustries. With a strong professional team,accumulated a wealth of technology, management experience, covering thecountry"s marketing network and branches, can provide users with fast andconvenient technical services. Since JSN Micro Flow Meter establishment, itrely on Siemens engineer’s powerful technology and high-quality service toquickly gain a good reputation in the instrumentation market. Main products:mircoflow meter,oval gear flow meter , electromagnetic flow meter,piston flowmeter,spur gear flow meter,gear pump,gear metering pump. Adhering to the"build Flow Meter’s aircraft carrier, contribute to China"s automationindustry.

 closed-loop management gear flow measurement

closed-loop management gear flow measurement

Withthe development of society, the state pays more and more attention to theprocess automation instrumentation industry. However, the Oval gear flow meter industryhas been in a vacancy and has been monopolized by major foreign brands such asMax, KRACHT, OVAL, etc. , People have long endured the expensive, longdelivery, the sale can not be resolved in time and so on, such as semiconductorchip cutting a set of equipment on the millions, once the instrument problems,loss unimaginable, the slayer saw these phenomena, Resolutely resigned assenior engineer in the position of Siemens, the establishment of ShanghaiJi-sheng Instruments Co., Ltd., with great concentration on research anddevelopment of gear flow meter. We have Oval gear flow meter has been awarded anumber of certificates, it is no exaggeration to say that Qishen production Ovalgear flow meter For example, many customers replace the OVAL LSF40 with ourCX-M5-AL because it costs less than half of the LSF40, but has twice the rangethan it does and has the same accuracy.

Shanghai JSN Micro Flow Meter Co., Ltd. is the second manufacturer ofmicro Oval gear flow meter in China. It is developed by Tu engineer (formerSiemens senior engineer) with independent intellectual property rights. Theproduction and processing equipment fully adopts Siemens CNC machining centerto ensure the minimum flow 0.1ml / min, which is rare in the world, theaccuracy of over 90% of peers. We can do more temperature 200C, the pressurecan be customized to 1000bar, many customers use it, but also unbelievable.Also domestic Most of the flowmeter use a year after the new calibration, butthe base depth meter after hundreds of conditions of medium test, the servicelife of more than 8 years, and without secondary calibration, since theestablishment of the base depth instrument Instrument determined to beworld-class flow meter, breaking the monopoly of international brands in themirco flow meter industry, so that customers can buy in the country realGerman-made quality flow meter.

gear flow measurement

closed-loop management gear flow measurement

Componentsand principles of the Oval gear flow meter - The measurement part of the flowmeter consists of two intermeshing gears and its housing (metering chamber).The measured medium mass per revolution of the gear is half-moon-shaped 4times, in the mirco flow meter hemispherical volume under certain conditions,as long as the measured gear rotation speed n, we can know the measured mediumflow.

 closed-loop management gear flow measurement

closed-loop management gear flow measurement

Technicaldata of CX-M Series micro oval Oval gear flow meter

Model

Flow  range

Accuracy

Connection  size

CX-M2

0.5~150ml/min

0.5%

G1/8"

CX-M3

3~300ml/min

0.5%

G1/8"

CX-M5

5~1000ml/min

0.5%

G1/8"

CX-M6

0.5~100L/H

0.5%

G1/4"

CX-M9

6~600L/H

0.5%

G1/4"

CX-M12

0.3~30L/Min

0.5%

G1/2"

CX-M25

0.5~100L/Min

0.5%

G1"


What are the precautions for the gear flow meter?

1) If the medium temperature is too high, or the pressure is too high, please inform us before purchasing, we can customize it for you.

2) When the pipeline is continuously operated and the flowmeter is to be installed in a horizontal pipeline, a bypass pipeline should be installed to facilitate cleaning and overhaul; when the flowmeter is installed on a vertical pipeline, the flowmeter should be installed on the bypass. In the pipeline, to prevent debris from falling into the instrument. When the fluid flows from bottom to top, the vertical tube in the upper part of the flowmeter should be as short as possible to reduce the precipitation of impurities in the upper piping.