adhesive mini flowmeter

Date:2017-02-01 source:
  adhesive mini flowmeter  

email: porter@microflowmeter.com Shanghai JSNMicro Flow Meter CO.,LTD.is a family company and it has more than 30 yearshistory. We are specialized in research of high quality flow meters, such as mircoflow meter,oval gear flow meter ,coriolis mass flow meter,electromagnetic flowmeter,piston flow meter, spur gear flow meter,gear pump,gear metering pump andso on. We devote ourselves to break the technology monopoly of foreigncountries. Our micro flow meter can replace Kracht, OVAL, SIKA and OMAGEforeign brands and so on. We have export our flow meters into more than 100countries and Shanghai JSN Micro Flow Meter CO.,LTD has already been a famous Automationinstrumentation company.

 adhesive mini flowmeter

adhesive mini flowmeter

Withthe development of society, the state pays more and more attention to theprocess automation instrumentation industry. However, the Oval gear flow meter industryhas been in a vacancy and has been monopolized by major foreign brands such asMax, KRACHT, OVAL, etc. , People have long endured the expensive, longdelivery, the sale can not be resolved in time and so on, such as semiconductorchip cutting a set of equipment on the millions, once the instrument problems,loss unimaginable, the slayer saw these phenomena, Resolutely resigned assenior engineer in the position of Siemens, the establishment of ShanghaiJi-sheng Instruments Co., Ltd., with great concentration on research anddevelopment of gear flow meter. We have Oval gear flow meter has been awarded anumber of certificates, it is no exaggeration to say that Qishen production Ovalgear flow meter For example, many customers replace the OVAL LSF40 with ourCX-M5-AL because it costs less than half of the LSF40, but has twice the rangethan it does and has the same accuracy.

Oval gear flow meter, belonging to a type of volumetric flowmeter,cylindrical shape, with import and export, according to the media with a customfilter. Small size, light weight, easy installation, compact structure, withouttoo much maintenance; other The range ratio is very wide, generally more than1: 100, the minimum flow rate can be measured to 0.3ml / min; and thelinearization accuracy can reach 0.5% FS of full scale, so the use is very wideand can be used for measuring, regulating, controlling and distributing Highand low viscosity, or corrosive liquids, and there are health-type,explosion-proof for a special environment.

mini flowmeter

adhesive mini flowmeter

Componentsand principles of the Oval gear flow meter - The measurement part of the flowmeter consists of two intermeshing gears and its housing (metering chamber).The measured medium mass per revolution of the gear is half-moon-shaped 4times, in the mirco flow meter hemispherical volume under certain conditions,as long as the measured gear rotation speed n, we can know the measured mediumflow.

 adhesive mini flowmeter

adhesive mini flowmeter

Technicaldata of Gear type flow meter

Model

K-factor

Minimum  flow

Flow  range

Accuracy

G0.025

0.025ml

0.001L/Min

0.008~2L/Min

0.5%

G0.04

0.04ml

0.004L/Min

0.2~4  L/min

0.5%

G0.1

0.4ml

0.008L/Min

0.01~8L/min

0.5%

G0.2

0.245ml

0.01L/Min

0.16~16  L/min

0.5%

G0.4

0.4ml

0.01L/Min

0.16~16  L/min

0.5%

G1

1.036ml

0.02L/Min

0.4~80  L/min

0.5%


Commonfault causes, troubleshooting

a. Thegear does not rotate: The gear is jammed by debris, the gear and cavity need tobe cleaned, and the filter is cleaned or replaced.

b. Thesmall flow error is too large: The flowmeter is installed in the wrongdirection, the best position goes up and down, or there are impurities to blockthe gear and need to be cleaned.

c. Theflow error is too large: The actual use flow range is less than or far greaterthan the flowmeter range. The corresponding flowmeter must be selected.

d. Noflow sensor signal: The gear is stuck or the circuit is connected incorrectlyor the circuit is damaged. The gear and cavity must be cleaned, or the circuitmust be correctly connected or replaced.