新闻资讯PCBanner 新闻资讯wapBanner
首页 > Flow Meters' Diary > News of Flow Meter > additive adder oval gear flow900 measurement
Submit a message
  • Name*
  • Tel*
  • Email*
  • Content*
  •  

Friendship tips

    Shanghai JSN Micro Flow Meter CO.,LTD as a high-tech industrial products manufacturing and complete sets of product sales, R & D, production, processing and sales as one, with independent import and export rights of enterprises.
    The company's main flow meter, level meter, and pressure controller, temperature controller, analytical instruments and other various types of instrumentation. To solve all kinds of problems, and provide complete sales service for customers with professional technical point of view.
International service telephone
(86)021-57632436

additive adder oval gear flow900 measurement

Date:2018-01-02 source:

  additive adder oval gear flow900 measurement   email: porter@microflowmeter.com

Shanghai JSN Micro Flow Meter CO.,LTD is located inShanghai Songjiang industry zone,with good location and convenienttransportation. We are the professional producer for micro flow meter,oval gearflow meter ,coriolis mass flow meter,electromagnetic flow meter,piston flowmete,gear flow meter,gear pump. We have rich experience incorporate management and production practice, especially in recent years,through the introduction of advanced domestic and foreign manufacturingtechnology, so that the factory"s management level and technical level hasleapt to a new level.We produce each series of flow meter and gear pump, complete specifications,advanced technology, excellent production equipment, strong technical force,complete inspection methods, quality in line with relevant standardspromulgated by the state and ministries, reliable performance. Annual outputand sales are far ahead of the industry. We are willing to join handswith all companies, Chinese and foreign investors, and Sihai people are lookingforward to making friends in the world, making them profitable to customers andbeing honest in the world.

 additive adder oval gear flow900 measurement

additive adder oval gear flow900 measurement

Onceupon a time, China"s manufacturing industry in the world"s processing plant hasalways been the "low quality" representative of the world. Inparticular, the Oval gear flow meter for automatic process control has theadvantages of large volume, large noise, small turndown ratio, , The use ofeasy to leak, instability and so on, leaving customers a headache is that manyproblems in the early stages of product does not appear, and in the event ofafter-sale is very troublesome, bothering money, these are domestic objectiveobjective existence of Oval gear flow meter Therefore, users buy Oval gear flowmeter is like buying lottery tickets, do not know sent to the installation siteOval gear flow meter is a blessing, in a sense, is a matter of course, whilethe base depth meter appeared to solve these problems in one fell swoop.

Oval gear flow meter, belonging to a type of volumetric flowmeter,cylindrical shape, with import and export, according to the media with a customfilter. Small size, light weight, easy installation, compact structure, withouttoo much maintenance; other The range ratio is very wide, generally more than1: 100, the minimum flow rate can be measured to 0.3ml / min; and thelinearization accuracy can reach 0.5% FS of full scale, so the use is very wideand can be used for measuring, regulating, controlling and distributing Highand low viscosity, or corrosive liquids, and there are health-type,explosion-proof for a special environment.



additive adder oval gear flow900 measurement

The Ovalgear flow meter consists of a metering box and a pair of gears mounted in themetering box. It forms a sealed initial moon cavity with the upper and lowercover plates as a unit of calculation of the primary displacement. When themeasured liquid enters the flow meter through the pipe, The pressure differencegenerated at the outlet pushes a pair of gears to continuously rotate, and theliquid measured by the initial cavity is continuously delivered to the outlet.The product of the number of rotations of the gear and four times of eachdisplacement is the measured liquid flow rate. The total flowmeter is mainlycomposed of a housing, a counter, a gear and a coupling (magnetic coupling andaxial coupling).

 additive adder oval gear flow900 measurement

additive adder oval gear flow900 measurement

Technicaldata of Gear type flow meter

Model

K-factor

Minimum  flow

Flow  range

Accuracy

G0.025

0.025ml

0.001L/Min

0.008~2L/Min

0.5%

G0.04

0.04ml

0.004L/Min

0.2~4  L/min

0.5%

G0.1

0.4ml

0.008L/Min

0.01~8L/min

0.5%

G0.2

0.245ml

0.01L/Min

0.16~16  L/min

0.5%

G0.4

0.4ml

0.01L/Min

0.16~16  L/min

0.5%

G1

1.036ml

0.02L/Min

0.4~80  L/min

0.5%


What are the precautions for the gear flow meter?

1) If the medium temperature is too high, or the pressure is too high, please inform us before purchasing, we can customize it for you.

2) When the pipeline is continuously operated and the flowmeter is to be installed in a horizontal pipeline, a bypass pipeline should be installed to facilitate cleaning and overhaul; when the flowmeter is installed on a vertical pipeline, the flowmeter should be installed on the bypass. In the pipeline, to prevent debris from falling into the instrument. When the fluid flows from bottom to top, the vertical tube in the upper part of the flowmeter should be as short as possible to reduce the precipitation of impurities in the upper piping.

Share to:


© 2016 Shanghai JSN Micro Flow Meter CO.,LTD  All rights reserved  Shanghai ICP preparation 07036704-1Map | Contact