additive adder oval flow measurement

Date:2018-01-03 source:

  additive adder oval flow measurement   email: porter@microflowmeter.com

ShanghaiJSN Micro Flow Meter CO.,LTD is a new high-tech enterprise which specialized inProduction,Sales for Flow Meter and Level instrument.We are located in one ofthe instrument production base Shanghai. We have many scientific and technicalpersonnel engaged in the development and production for instruments,.productperformance and quality reach the domestic advanced level. The company"svarious types of processing calibration equipment, can produce various types ofspecial instruments outside the base type. We also have a group of strongtechnical experience abundant after-sales service personnel, on-site serviceand installation commissioning for you.Main products:Super Micro Liquid FlowMeter,Oval gear flow meter ,Mass Flow Meter,Circle Spur Gear Flow Meter,GearPump,Gear metering Pump etc. We use advancedproduction equipment, mature processing technology, accurate inspection andmeasurement to allow you to buy a satisfactorily,comfortable, with confidence, professional flow meter and metering pumpmanufacturers.

 additive adder oval flow measurement

additive adder oval flow measurement

Ovalgear flow meter  is widely used inpetroleum, chemical and hydraulic industries due to its advantages of highprecision, simple installation, stable performance and goodrepeatability.However, the Oval gear flow meter that can be produceddomestically can only be applied due to the impatience of high pressure In thelow pressure occasion, the high pressure measurement occasion can only rely onthe foreign imported high pressure flowmeter.Therefore, the research of thehigh pressure Oval gear flow meter will help to expand the domestic applicationof the Oval gear flow meter and promote the development of the domestic flowmeasurement. Deep instrumentation independent research and development of the Ovalgear flow meter pressure up to 1000bar, it can be said has reached a higherlevel in the world, and obtain measurement certificate.

Oval gear flow meter, belonging to a type of volumetric flowmeter,cylindrical shape, with import and export, according to the media with a customfilter. Small size, light weight, easy installation, compact structure, withouttoo much maintenance; other The range ratio is very wide, generally more than1: 100, the minimum flow rate can be measured to 0.3ml / min; and thelinearization accuracy can reach 0.5% FS of full scale, so the use is very wideand can be used for measuring, regulating, controlling and distributing Highand low viscosity, or corrosive liquids, and there are health-type,explosion-proof for a special environment.

oval flow measurement

additive adder oval flow measurement

The Ovalgear flow meter is a volumetric flow meter that consists of a flow chamber in achamber and one or several elements that are rotated by fluid flow to form aflow meter. Leakage between the rotating element and the inner wall and theselected working range The internal flow rate is negligible. The rotation ofthe element is transmitted mechanically or by other means to the indicatingdevice to indicate the volume flow of the fluid flowing through.

 additive adder oval flow measurement

additive adder oval flow measurement

Technicaldata of Gear type flow meter

Model

K-factor

Minimum  flow

Flow  range

Accuracy

G0.025

0.025ml

0.001L/Min

0.008~2L/Min

0.5%

G0.04

0.04ml

0.004L/Min

0.2~4  L/min

0.5%

G0.1

0.4ml

0.008L/Min

0.01~8L/min

0.5%

G0.2

0.245ml

0.01L/Min

0.16~16  L/min

0.5%

G0.4

0.4ml

0.01L/Min

0.16~16  L/min

0.5%

G1

1.036ml

0.02L/Min

0.4~80  L/min

0.5%


Commonfault causes, troubleshooting

a. Thegear does not rotate: The gear is jammed by debris, the gear and cavity need tobe cleaned, and the filter is cleaned or replaced.

b. Thesmall flow error is too large: The flowmeter is installed in the wrongdirection, the best position goes up and down, or there are impurities to blockthe gear and need to be cleaned.

c. Theflow error is too large: The actual use flow range is less than or far greaterthan the flowmeter range. The corresponding flowmeter must be selected.

d. Noflow sensor signal: The gear is stuck or the circuit is connected incorrectlyor the circuit is damaged. The gear and cavity must be cleaned, or the circuitmust be correctly connected or replaced.


Share to: