新闻资讯PCBanner 新闻资讯wapBanner
首页 > Flow Meters' Diary > News of Flow Meter > Toluene mini flow meter
Submit a message
  • Name*
  • Tel*
  • Email*
  • Content*
  •  

Friendship tips

    Shanghai JSN Micro Flow Meter CO.,LTD as a high-tech industrial products manufacturing and complete sets of product sales, R & D, production, processing and sales as one, with independent import and export rights of enterprises.
    The company's main flow meter, level meter, and pressure controller, temperature controller, analytical instruments and other various types of instrumentation. To solve all kinds of problems, and provide complete sales service for customers with professional technical point of view.
International service telephone
(86)021-57632436

Toluene mini flow meter

Date:2017-02-01 source:
  Toluene mini flow meter  

email: [email protected]  ShanghaiJSN Micro Flow Meter CO.,LTD is in the wave of market economy struggle,development has been decades, has a high visibility, enjoy good reputation.Mainproducts: super micro liquid flow meter,oval gear flow meter ,mass flow meter,circle spur gear flow meter,gear pump,gear metering pump etc instrument. Withits excellent cost-effectiveness for the user"s favor. We have a serious workattitude, solid business foundation, strong sense of solidarity andcooperation, a strong professional and technical staff.

 Toluene mini flow meter

Toluene mini flow meter

Ovalgear flow meter  is widely used inpetroleum, chemical and hydraulic industries due to its advantages of highprecision, simple installation, stable performance and goodrepeatability.However, the Oval gear flow meter that can be produceddomestically can only be applied due to the impatience of high pressure In thelow pressure occasion, the high pressure measurement occasion can only rely onthe foreign imported high pressure flowmeter.Therefore, the research of thehigh pressure Oval gear flow meter will help to expand the domestic applicationof the Oval gear flow meter and promote the development of the domestic flowmeasurement. Deep instrumentation independent research and development of the Ovalgear flow meter pressure up to 1000bar, it can be said has reached a higherlevel in the world, and obtain measurement certificate.

Oval gear flow meter, belonging to a type of volumetric flowmeter,cylindrical shape, with import and export, according to the media with a customfilter. Small size, light weight, easy installation, compact structure, withouttoo much maintenance; other The range ratio is very wide, generally more than1: 100, the minimum flow rate can be measured to 0.3ml / min; and thelinearization accuracy can reach 0.5% FS of full scale, so the use is very wideand can be used for measuring, regulating, controlling and distributing Highand low viscosity, or corrosive liquids, and there are health-type,explosion-proof for a special environment.

mini flow meter

Toluene mini flow meter

Ovalgear flow meter Through the rotation of the gear cavity, through a series ofdeceleration and speed ratio adjustment mechanism, directly connected with theindicator on the instrument panel, and through the mechanical counter for thetotal display. Or remote display is mainly through The decelerated gear drivesthe permanent magnet to rotate so that the contacts of the spring relay (Hallsensor) are closed or opened synchronously at the same rotation frequency asthe permanent magnet, thereby sending one electric pulse to the other displayinstrument.

 Toluene mini flow meter

Toluene mini flow meter

Technicaldata of Gear type flow meter

Model

K-factor

Minimum  flow

Flow  range

Accuracy

G0.025

0.025ml

0.001L/Min

0.008~2L/Min

0.5%

G0.04

0.04ml

0.004L/Min

0.2~4  L/min

0.5%

G0.1

0.4ml

0.008L/Min

0.01~8L/min

0.5%

G0.2

0.245ml

0.01L/Min

0.16~16  L/min

0.5%

G0.4

0.4ml

0.01L/Min

0.16~16  L/min

0.5%

G1

1.036ml

0.02L/Min

0.4~80  L/min

0.5%


What is the reason why the tiny gauge flow meter is larger than the actual value? the reason:1. The flow has a large pulse.2. The medium is mixed with gas.3. Medium viscosity is too large.Treatment measures:1. Reduce the pulsation of the flow in the pipeline.2. Install degasifier.3. Recalibrate, replace the adjustment gear pair and correct it.
Share to:


© 2016 Shanghai JSN Micro Flow Meter CO.,LTD  All rights reserved  Shanghai ICP preparation 07036704-1Map | Contact