新闻资讯PCBanner 新闻资讯wapBanner
首页 > Flow Meters' Diary > News of Flow Meter > Toluene gear flow meter
Submit a message
  • Name*
  • Tel*
  • Email*
  • Content*
  •  

Friendship tips

    Shanghai JSN Micro Flow Meter CO.,LTD as a high-tech industrial products manufacturing and complete sets of product sales, R & D, production, processing and sales as one, with independent import and export rights of enterprises.
    The company's main flow meter, level meter, and pressure controller, temperature controller, analytical instruments and other various types of instrumentation. To solve all kinds of problems, and provide complete sales service for customers with professional technical point of view.
International service telephone
(86)021-57632436

Toluene gear flow meter

Date:2017-01-20 source:

  Toluene gear flow meter  

email: porter@microflowmeter.com  ShanghaiJSN Micro Flow Meter CO.,LTD is an automatic meter production R&Denterprise approved by the Chinese government; it is mainly engaged in theresearch, development, and manufacturing of high-end technologies, processesand related equipment in the field of fluid measurement and control to meet theneeds of China and the world for fluid measurement and control equipment. Andthe higher requirements of the products. The company adopts internationaladvanced product design, manufacturing and management technologies, anddevelopment, produce the high quality super micro liquid flow meter,oval gearflow meter ,mass flow meter, circle spur gear flow meter,gear pump,gearmetering pump to meet China and world’s higher requirement. Wenot only has superior high-tech comprehensive capabilities and strict qualitymanagement, measurement management and other systems as well as improvedprocessing and testing methods, but also has a talent team that has madeimportant contributions to the development of flow meters and pumps in Chinaand the world.

 Toluene gear flow meter

Toluene gear flow meter

Ovalgear flow meter  is widely used inpetroleum, chemical and hydraulic industries due to its advantages of highprecision, simple installation, stable performance and goodrepeatability.However, the Oval gear flow meter that can be produceddomestically can only be applied due to the impatience of high pressure In thelow pressure occasion, the high pressure measurement occasion can only rely onthe foreign imported high pressure flowmeter.Therefore, the research of thehigh pressure Oval gear flow meter will help to expand the domestic applicationof the Oval gear flow meter and promote the development of the domestic flowmeasurement. Deep instrumentation independent research and development of the Ovalgear flow meter pressure up to 1000bar, it can be said has reached a higherlevel in the world, and obtain measurement certificate.

Oval gear flow meter, belonging to a type of volumetric flowmeter,cylindrical shape, with import and export, according to the media with a customfilter. Small size, light weight, easy installation, compact structure, withouttoo much maintenance; other The range ratio is very wide, generally more than1: 100, the minimum flow rate can be measured to 0.3ml / min; and thelinearization accuracy can reach 0.5% FS of full scale, so the use is very wideand can be used for measuring, regulating, controlling and distributing Highand low viscosity, or corrosive liquids, and there are health-type,explosion-proof for a special environment.

gear flow meter

Toluene gear flow meter

The Ovalgear flow meter is a volumetric flow meter that consists of a flow chamber in achamber and one or several elements that are rotated by fluid flow to form aflow meter. Leakage between the rotating element and the inner wall and theselected working range The internal flow rate is negligible. The rotation ofthe element is transmitted mechanically or by other means to the indicatingdevice to indicate the volume flow of the fluid flowing through.

 Toluene gear flow meter

Toluene gear flow meter


Item

model

K-factor

The minimum flow

Flow range

Connection size

Gear flow meter

CX-G0.025-P-AL

0.025ml

0.001L/Min

0.004~1 L/min

G1/8

gear flow meter

CX-G0.025-P-SS

0.025ml

0.001L/Min

0.004~1 L/min

G1/8

gear flow meter

CX-G0.04-P-AL

0.04ml

0.004L/min

0.01~2L/min

G1/4

gear flow meter

CX-G0.04-P-SS

0.04ml

0.004L/min

0.01~2L/min

G1/4

gear flow meter

CX-G0.1-P-AL

0.1ml

0.008L/min

0.02~4L/min

G3/8

gear flow meter

CX-G0.1-P-SS

0.1ml

0.008L/min

0.02~4L/min

G3/8

gear flow meter

CX-G0.2-P-AL

0.245ml

0.01L/Min

0.08~8L/min

G3/8

gear flow meter

CX-G0.2-P-SS

0.245ml

0.01L/Min

0.08~8L/min

G3/8

gear flow meter

CX-G0.4-P-AL

0.4ml

0.01L/Min

0.1~20L/min

G1/2

gear flow meter

CX-G0.4-P-SS

0.4ml

0.01L/Min

0.1~20L/min

G1/2

gear flow meter

CX-G1-P-AL

1ml

0.02L/Min

0.2~40L/min

G1/2

gear flow meter

CX-G1-P-SS

1ml

0.02L/Min

0.2~40L/min

G1/2

gear flow meter

CX-G2-P-AL

2ml

0.04L/Min

0.5-60L/min

G3/4

gear flow meter

CX-G2-P-SS

2ml

0.04L/Min

0.5-60L/min

G3/4

Remark: Hightemperature, high pressure, high frequency, special connection, specialmaterials, two-way measurement, etc. can be customized


Commonfault causes, troubleshooting

a. Thegear does not rotate: The gear is jammed by debris, the gear and cavity need tobe cleaned, and the filter is cleaned or replaced.

b. Thesmall flow error is too large: The flowmeter is installed in the wrongdirection, the best position goes up and down, or there are impurities to blockthe gear and need to be cleaned.

c. Theflow error is too large: The actual use flow range is less than or far greaterthan the flowmeter range. The corresponding flowmeter must be selected.

d. Noflow sensor signal: The gear is stuck or the circuit is connected incorrectlyor the circuit is damaged. The gear and cavity must be cleaned, or the circuitmust be correctly connected or replaced.


Share to: